Home/Products/Plastic Fans/Pulley and Belt Coupling
Plastic fans

Fans with Pulley and Belt Coupling

MP / MM series · Indirect drive for medium and high pressure

Range of corrosion-resistant plastic fans for medium and high pressure. The pulley and belt transmission allows the impeller speed to be adjusted to optimise the operating point and reach the highest pressures in the TECNIUM range.

Flow rates up to 120,000 m³/h and pressures up to 7,000 Pa.

Fan with pulley and belt transmission - MP/MM series

MP / MM series with metallic base plate and pulley drive

The MP/MM series is built with a metallic base plate and pulleys, separating the motor from the impeller and allowing the transmission ratio to be adjusted to the exact process conditions.

  • Flow rates up to 120,000 m³/h
  • Pressures up to 7,000 Pa
  • Built in fibreglass-reinforced polyester (FRP). Thermoplastic lining available
  • Mechanical torque transmitted to the impeller via metallic key and large-surface steel hub
  • Integrated metallic baseplate with motor and accessible belt tensioning

Performance and configuration

SeriesMP / MM with base plate and pulleys
Maximum flow rateUp to 120,000 m³/h
Maximum pressureUp to 7,000 Pa
ConstructionFRP with optional thermoplastic lining
TransmissionMetallic key + large-surface steel hub

Four configurations to match the service

Seal selected according to the gas being handled, temperature and tightness requirements.

R

Sealing ring

Standard services

S

Leak reducer

Additional leak reduction

C

Mechanical seal

Toxic or hazardous gases

E

Automatic gasket

Reinforced tightness

Anticorrosive thermoplastics and composites

The casing and impeller are manufactured in solid thermoplastic or fibreglass-reinforced polyester depending on the contaminant matrix and gas temperature.

PVDFPolyvinylidene fluoride — strong oxidising agents and high temperature
PPPolypropylene — acids, alkalis and most industrial chemicals
FRP (GRP)Fibreglass-reinforced polyester — large formats and high stiffness
PVCPolyvinyl chloride — chemical services at low-medium temperature

FAQs on pulley-driven fans

The most common queries about indirect coupling, seal selection and materials.

Why choose a pulley and belt drive over direct coupling?

A pulley drive decouples the impeller speed from the motor’s nominal speed. That means you can fine-tune the ratio to obtain exactly the flow rate and pressure your process requires, reaching higher values (up to 120,000 m³/h and 7,000 Pa) than can be achieved with direct coupling. In addition, during operation the ratio can be changed by changing the pulleys if the process conditions evolve.

What are the differences between the MP and MM series?

Both are fans with a base plate and pulley transmission. The differences lie in the construction size, the flow-pressure curve and the motor power. TECNIUM selects the exact version based on the requested operating point (flow and pressure) and the space constraints at the customer’s site.

Which sealing system should I choose for the gas being treated?

The R ring is the most economical option for general corrosive gases without special tightness requirements. The S adds additional leak reduction. The C mechanical seal is the choice when handling toxic or hazardous gases where an external leak is unacceptable. The E automatic gasket offers reinforced tightness in applications with more demanding pressures or hazardous atmospheres.

FRP or solid thermoplastic?

FRP (fibreglass-reinforced polyester) is the usual choice for large fans because it combines excellent chemical resistance, light weight and structural stiffness. For especially aggressive gases (HF, concentrated oxidising acids), internal thermoplastic linings (PP, PVDF, PVC) are used over the FRP structure, combining the best of both worlds. TECNIUM defines the optimum solution on a case-by-case basis.

Does it require more maintenance than direct coupling?

Yes, belt transmission requires periodic inspection of belt condition and tension. It is straightforward and inexpensive maintenance, but it must be taken into account. In return, it provides speed flexibility and greater capacity. For services where maintenance must be minimal and pressure/flow requirements are moderate, the direct coupling (MD series) may be preferable.

Is an ATEX version available?

Yes. The MP/MM series supports ATEX certified configurations under Directive 2014/34/EU for explosive atmospheres. They include an ATEX motor, antistatic materials in impeller and casing, and earthing appropriate to the required protection level. This is the standard configuration in plants with flammable solvents, biogas or processes with zone classification.

More information

Send us your details and we will advise you

We will help you size the optimum MP/MM fan from your gas, flow rate, pressure and space constraints.

  • Size and material selection according to the gas
  • Sealing configuration adapted to the service
  • ATEX versions available
  • Integration with scrubbing towers and biofilters

Request information

Complete the form and our technical team will contact you.

    Explore our full range of fans

    Discover TECNIUM plastic fans with direct or pulley coupling for any flow rate and pressure.